Our website uses essential cookies to improve your experience; with your consent, we may also use Google Analytics cookies to measure site usage and Google Ads cookies for advertising measurement and remarketing.

Business solutions and partnerships

Charging solutions for businesses and housing complexes

Let's evaluate together the products and collaboration options that suit your company's line of business and projects.

Let's evaluate your project

AC and DC electric vehicle charging solutions, built in Yalova under the Ümelsan roof.

HIMS Tech manufactures commercial AC chargers and 30–120 kW DC fast charging stations for factories, workplaces, residential complex management, parking facilities and fleet sites. Depending on the model, commercial AC chargers offer RFID user authorization, remote management via OCPP 1.6J and a MID-certified energy meter. Installation requires an on-site survey; surveys and installations are carried out by authorized HIMS dealers.

Choose the solution path that suits you

Model in the image: DC40
Model in the image: DC40

OEM project request

OEM manufacturing under your own brand: DC stations, station cables and sockets

30–120 kW DC charging stations, Type 2 station cables and station sockets are manufactured with your own brand and logo. The model, branding, quantity and lead time are confirmed at the quotation stage.

Factories and workplaces

Plan your business's charging needs at your own site

Installing a charging point at your own site can reduce off-site charging trips and let you schedule vehicle charging around your operations.

Assess energy use, operating requirements and the proposed charging arrangement as part of the project review.

HIMS DC fast-charging solutions

30 · 40 · 60 · 80 · 120 kW

AC option for vehicles parked for long periods

22 kW AC

Company vehicles

DC charging options are considered for company vehicles that need to head back out into the field during the day and for heavily used fleets.

Employee and visitor vehicles

A suitable charger and usage plan for your own vehicles, employees or visitors.

Parking time

22 kW AC chargers can be used for vehicles that stay at the facility during working hours or overnight. Depending on the AC power the vehicles support, DC and AC chargers can be used together at the same facility.

Site and electrical capacity

The appropriate charger power is determined by your vehicle models, your daily usage, the time you can set aside for charging and your facility's electrical infrastructure.

Illustrative application image. Models shown: DC40 and DC120.
Illustrative application image. Models shown: DC40 and DC120.
Let's evaluate your project

The site survey and installation are carried out by authorised HIMS dealers that provide installation services.

Business, residential complex and car park use

Compare our commercial AC and DC models below by application.

AC models suitable for commercial use

HCDP-22T/7T is a commercial wall-mounted charging unit for shared use; it offers OCPP 1.6J-based authorisation and Ethernet/4G/Wi-Fi communication. HCZS-2x22T (pedestal) and HCDS-2x22T (wall-mounted) charge two vehicles at the same time (2×22 kW); they include a MID-certified meter, RFID and OCPP 1.6J, and are IP54 protected. HCZS-2x22T is suited to car park and fleet use, and HCDS-2x22T to car parks and commercial areas.

User authentication, metering and management

RFID provides user authorisation. HCDP-22T and HCDP-7T support RFID/OCPP-based authorisation. HCZS-2x22T and HCDS-2x22T each have two MID-certified meters. OCPP enables communication with a compatible charging-management system; the hardware, network connection and software must be assessed for the selected model.

DC stations for fast charging

Our 30–120 kW DC stations have CCS2 connectors with 5 m cables and suit commercial charging sites such as shopping centres, hotels, fuel stations and fleet depots. DC40, DC60, DC80 and DC120 have a 7-inch touchscreen, RFID, OCPP 1.6J and Ethernet/4G; DC30 is wall-mounted, while DC60, DC80 and DC120 are floor-mounted.

Energy management (DLB, solar)

The HCDS-2x22T product page lists solar energy and dynamic load balancing (DLB) support. Installation requires an on-site survey and project design; authorised HIMS dealers offering these services carry out the survey and installation.

Dealer site surveys, installation and warranty

The site survey and installation are carried out by authorised HIMS dealers that provide installation services; our customer representative refers you to the appropriate authorised dealer. For wholesale supply and project-based DC charging station enquiries, contact our team. List prices are not published on the site. Prices are provided in a project-specific quotation based on the device model, quantity and installation scope. In the charging calculator’s recommendations, wall-mounted chargers, commercial AC products and DC products have a 'Book a Site Survey' button; other products have a 'Get a Quote' button. On product pages, you can use the 'Request a quote from an authorized dealer' link. The warranty period is 2 years; faulty installation and unauthorised intervention are not covered by the warranty.

How do we work?

  1. Share your needs

    Submit your company, vehicle and site details through the application form.

  2. Review the options

    We determine suitable charger options based on vehicle models, daily usage, parking times and electrical capacity.

  3. Quote and plan

    Together, we assess charger selection based on your facility’s electrical infrastructure and usage, and confirm price, delivery and service scope at the quotation stage.

  4. Site survey and installation

    For requests that require installation, the site survey and installation are carried out by authorised HIMS dealers that provide installation services.

Frequently asked questions

Can more than one vehicle be charged at the same time?

HCZS-2x22T and HCDS-2x22T offer a maximum of 2 × 22 kW across two outputs; actual power depends on the charging power accepted by the vehicles and the electrical supply. On DC models with two CCS2 outputs in the HCDC-S2 family, two vehicles can charge simultaneously, with the station’s total power shared equally between the two outputs. An on-site survey and project design are required for installation; authorised HIMS dealers offering these services carry out the survey and installation.

How do I authorise users?

Models with RFID readers include HEVC-22-T, HCDK-22-B/S, HCDP-22T/7T, HCDS-2x22T, HCZS-2x22T and 40–120 kW DC stations. HEVC-22-T and HCDP-22T/7T also offer OCPP-based authorisation; the method used depends on support from the model and management infrastructure.

Are there models with a meter?

Yes. HCZS-2x22T and HCDS-2x22T have two MID-certified meters, measuring consumption separately for each output. An optional MID-approved meter can also be fitted to the HCMA mounting pedestal used with wall-mounted stations.

Does it work with solar energy?

The HCDS-2x22T product page states support for solar energy and dynamic load balancing (DLB). An on-site survey and project design are required for implementation details.

Can I manage the chargers remotely?

Models supporting OCPP 1.6J include HCTK-11-PS-S, HCDK-22-B/S, HCDP-22T/7T, HCZS-2x22T, HCDS-2x22T and 40–120 kW DC stations. Remote management requires compatible management software or a charging network platform; monitoring and reporting capabilities also depend on that software’s functions.

Should we choose AC or DC for our factory?

Consider AC for longer parking periods and DC for shorter stops by CCS2-compatible vehicles. Charger power and quantity depend on the vehicles’ accepted charging power, daily energy needs, available charging time and the facility’s electrical capacity.

What environmental conditions are commercial AC stations suitable for?

HCDP-22T/7T is rated IP65 and IK10; HCZS-2x22T and HCDS-2x22T are rated IP54. Operating temperatures are −30…+50 °C for HCDP-22T/7T and HCDS-2x22T, and −30…+55 °C for HCZS-2x22T.

What electrical connection do DC stations require?

Our DC stations operate on an AC 400 V, 50/60 Hz three-phase supply. The 30 kW model is wall-mounted; the 60–120 kW models are floor-mounted. Supply capacity and cable cross-section are determined during the site survey.

Application

Let's work together.

Share your number of vehicles, vehicle models and the province where your facility is located; let's evaluate charger options and electrical infrastructure that suit your needs.

  • Your request is forwarded to our sales team; we will get back to you by email or phone.
  • For requests that require a site survey and installation, the customer is referred to an authorised HIMS dealer.